Effectiveness of the Domestic Wastewater Quality Monitoring System at a General Hospital’s Wastewater Treatment Plant

Authors

  • Debora Maria Manullang Universitas Pendidikan Ganesha, Indonesia
  • I Made Gunamantha Universitas Pendidikan Ganesha, Indonesia
  • Putu Indra Christiawan Universitas Pendidikan Ganesha, Indonesia

DOI:

https://doi.org/10.54518/rh.6.4.2026.1495

Keywords:

Compliance, Corrective Action, Hospital Wastewater Treatment, Wastewater Quality Monitoring

Abstract

Hospital domestic wastewater carries organic and microbiological pollution loads requiring both adequate treatment and reliable monitoring; however, effectiveness is often judged solely from laboratory pass/fail results rather than the monitoring system itself. This study examines the effectiveness of the wastewater quality monitoring system at a general hospital’s wastewater treatment plant in Buleleng Regency, Bali, Indonesia, using five years of outlet monitoring data (2021–2025). A sequential explanatory mixed-methods design was applied: a quantitative phase analyzed 16 laboratory test records for trend and compliance, followed by a qualitative phase comprising a document checklist, a gap analysis against national wastewater regulation, a SWOT analysis, and limited staff clarification. Results show 93.75% of test results met the applicable standard, with one pH exceedance in December 2022 never followed by documented corrective action. Monitoring frequency reached the minimum target in only three of four fully recorded years, and no single test covered the complete mandatory parameter set. Gap analysis across nine monitoring-system aspects found none fully compliant with ideal provisions. Treatment performance is generally sound, but the monitoring system remains structurally weak in governance. Priority strategies identified are a formal corrective-action procedure, a standardized operation-and-maintenance logbook, and completion of the mandatory testing parameter package.

Downloads

Download data is not yet available.

References

Ali, A. (2021). Determining mediating role of managerial commitment and technological capability between environmental management accounting and organisational efficiency: a case of middle eastern countries. Arthatama: Journal of Business Management and Accounting, 5(2), 27-38.

Amin, N., Foster, T., Shimki, N. T., & Willetts, J. (2024). Hospital wastewater (HWW) treatment in low-and middle-income countries: A systematic review of microbial treatment efficacy. Science of the Total Environment, 921(3), 170-184. https://doi.org/10.1016/j.scitotenv.2024.170994.

Arumdani, R. S., Azhari, F. F., Fadhillah, I. N., Dirgantara, I. M. B., & Soetanto, H. (2024). Recent trends in customer centricity: A systematic literature review in sustainability economics. Research Horizon, 4(4), 369-378. https://doi.org/10.54518/rh.4.4.2024.347.

Awad, H., Mossad, M., Mahanna, H., Foad, M., & Gar Alalm, M. (2024). Comparative assessment of different scenarios for upgrading activated sludge wastewater treatment plants in developing countries. Science of the Total Environment, 5(6), 168-182. https://doi.org/10.1016/j.scitotenv.2023.168022.

Baeti, M. K., Raharjo, M., Dewanti, N. A. Y., & Sulistiyani, S. (2022). Effectiveness of the wastewater treatment plant (WWTP) of Roemani Muhammadiyah General Hospital, Semarang. Jurnal Kesehatan Masyarakat (Undip), 10(3), 281–289. https://doi.org/10.14710/jkm.v10i3.32736.

Birhan, D., Aderaw, Z., Agdew, E., Siferih, M., & Kabir, H. (2024). Satisfaction of chronic patients with community-based health insurance schemes and related factors: Explanatory sequential mixed methods study. PLOS Global Public Health, 4(8), 33-74. https://doi.org/10.1371/journal.pgph.0003374.

Creswell, J. W., & Plano Clark, V. L. (2018). Designing and conducting mixed methods research (3rd ed.). London: Sage Publications.

Fahira, R. A., & Slamet, A. (2022). Performance evaluation of the wastewater treatment plant (WWTP) of Indramayu Regional General Hospital Class B and Y Private Hospital Class B Cirebon. Jurnal Teknik ITS, 11(3), 100–106. https://doi.org/10.12962/j23373539.v11i3.92058.

Fatimazahra, S., Latifa, M., Laila, S., & Monsif, K. (2023). Review of hospital effluents: Special emphasis on characterization, impact, and treatment of pollutants and antibiotic resistance. Environmental Monitoring and Assessment, 195(3), 393-408. https://doi.org/10.1007/s10661-023-11002-5.

Government of Bali. (2016). Governor of Bali Regulation Number 16 of 2016 concerning Wastewater Quality Standards.

Government of Indonesia. (2021). Government Regulation Number 22 of 2021 concerning the Implementation of Environmental Protection and Management.

Government of Indonesia. (2021). Government Regulation Number 47 of 2021 concerning the Implementation of Hospital Affairs.

Government of Indonesia. (2023). Law Number 6 of 2023 concerning Stipulation of Government Regulation in Lieu of Law Number 2 of 2022 on Job Creation into Law.

Gunn, R., Watkins, S. L., Boston, D., Rosales, A. G., Massimino, S., Navale, S., ... & McMullen, C. K. (2024). Evaluation of a remote patient monitoring program during the COVID-19 pandemic: retrospective case study with a mixed methods explanatory sequential design. JMIR Formative Research, 8(4), 57-72. https://doi.org/10.2196/55732.

International Organization for Standardization. (2015). ISO 14001:2015. Environmental management systems: Requirements with guidance for use. ISO. Retrieved on January 24, 2026, from https://www.iso.org/standard/60857.html.

Ivankova, N. V., Creswell, J. W., & Stick, S. L. (2006). Using mixed-methods sequential explanatory design: From theory to practice. Field Methods, 18(1), 1–20. https://doi.org/10.1177/1525822X05282260.

Khan, M. T., Ahmad, R., Liu, G., Zhang, L., Santagata, R., Lega, M., & Casazza, M. (2024). Potential environmental impacts of a hospital wastewater treatment plant in a developing country. Sustainability, 16(6), 22-33. https://doi.org/10.3390/su16062233.

Maddusa, S. S. (2019). Efektivitas instalasi pengolahan air limbah berdasarkan parameter biological oxygen demand, chemical oxygen demand dan derajat keasaman di rumah sakit umumgmim pancaran kasih Manado. Kesmas, 8(6), 608–615.

Ministry of Environment and Forestry of the Republic of Indonesia. (2016). Regulation of the Minister of Environment and Forestry Number P.68/MENLHK/SETJEN/KUM.1/8/2016 concerning Domestic Wastewater Quality Standards.

Ministry of Environment/Environmental Control Agency of the Republic of Indonesia. (2025). Regulation of the Minister of Environment/Environmental Control Agency Number 11 of 2025 concerning Wastewater Quality Standards and Wastewater Treatment Technology Standards for Domestic Wastewater.

Ministry of Health of the Republic of Indonesia. (2019). Regulation of the Minister of Health Number 7 of 2019 concerning Hospital Environmental Health.

Mondal, B., & Fakhruddin, A. N. M. (2025). Characterization of wastewater of a COVID-19 dedicated hospital (SARI-ITC), Teknaf, Cox’s Bazar and its impact on ecosystem. International Journal of Research and Scientific Innovation, 12(8), 2014–2024. https://doi.org/10.51244/IJRSI.2025.120800181

Rahmat, B., & Mallongi, A. (2018). Characteristics and quality study of BOD and COD in wastewater of Lanto Dg. Pasewang Regional General Hospital, Jeneponto Regency. Jurnal Nasional Ilmu Kesehatan, 1(2), 1–16.

Rhomadhoni, M. N., & Ayu, F. (2019). Evaluasi hasil pengolahan limbah cair pada instalasi pengolahan limbah cair salah satu Rumah Sakit Swasta di Kota Surabaya. Jurnal Ilmiah Teknik Lingkungan, 11(2), 24-29.

Sharma, C., Gupta, S., & Kumar, V. (2024). Hospital-associated effluents: the masked environmental threat that needs urgent attention and action. Discover Applied Sciences, 7(1), 40-52. https://doi.org/10.1007/s42452-024-06456-2.

Starkl, M., Brunner, N., Das, S., & Singh, A. (2022). Sustainability assessment for wastewater treatment systems in developing countries. Water, 14(2), 241-254. https://doi.org/10.3390/w14020241.

Tulashie, S. K., Kotoka, F., Kholi, F. K., Aggor-Woananu, S. E., & Tetteh, G. R. (2018). Assessment and remediation of pollutants in Ghana’s Kete-Krachi District hospital effluents using granular and smooth activated carbon. Heliyon, 4(8), 69-86. https://doi.org/10.1016/j.heliyon.2018.e00692.

Ulfah, U., Sarto, S., Iravati, I.(2024). Evaluasi pengelolaan limbah cair di rumah “X”. Jurnal Kesmas Jambi, 1(1), 40-51.

Waang, D. G., Fernandez, H., & Ramang, R. (2016). Analisis efektivitas instalasi pengolahan air limbah dan penilaian masyarakat terhadap pengolahan limbah cair Rumah Sakit Umum WZ Yohanes Kupang. Bumi Lestari Journal of Environment, 16(2), 92-106. https://doi.org/10.24843/blje.2016.v16.i02.p02.

Wibowo, A., & Yogisutanti, G. (2023). Efektivitas instalasi pengolahan air limbah secara biologis aerobik terhadap penurunan kadar COD, BOD, PH, TSS dan MPN Coliform di Rumah Sakit Paru DR. HA Rotinsulu. Jurnal Ilmu Kesehatan Immanuel, 17(1), 100-116.

Downloads

Published

2026-08-25

How to Cite

Manullang, D. M., Gunamantha, I. M., & Christiawan, P. I. (2026). Effectiveness of the Domestic Wastewater Quality Monitoring System at a General Hospital’s Wastewater Treatment Plant. Research Horizon, 6(4), 1809–1822. https://doi.org/10.54518/rh.6.4.2026.1495

Similar Articles

<< < 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 > >> 